Power Quality Monitor
Brand : ACCUENERGY
Model : Acuvim 3
Size : W187mm x H132mm x 88.2mm
- Features
• Top class of Power Quality Meter with revenue grade accuracy 0.1s with Touch screen control
• Fast Log captures instantaneous power quality events and saves a report for future assessment
• Reduce downtime and prevent unexpected equipment errors with sophisticated power quality metering with event notification via email, digital output, or relay output
• Touchscreen 7" (17.78 cm), built-in web interface for real-time analysis on the go
• Receive instant email notifications to stay informed of system or equipment failures from anywhere
• IEC 61000-4-30 Class-A Compliant Metering of Split-Second Power Malfunctions
• IEC 61557-12 Class 0.1 Accuracy Compliant for Voltage/Current RMS
• IEC 62053-22 Class 0.1s and ANSI C12.20 Class 0.1 Accuracy for Active Energy
• IEC 62053-24 Class 0.5s Accuracy for Reactive Energy
• Multi-protocol support: Modbus-RTU, Modbus-TCP/IP, BACnet-IP, DNP3 TCP, IEC 61850, & SNMP
• PMU (IEEE C37.118) for fast and reliable synchrophasor measurement
• Waveform Capture detection up to 512 sample/cycle and stored in COMTRADE format
• Time of Use TOU with eight tariff and up to twelve billing periods
• Fast Log capture with 1 cycle RMS
• 100 dataloggers with user-selectable logging interval and parameters
• Data post: HTTP/HTTPs, SFTP, and email
Power quality metering
IEC 61000-4-30 Class-A compliant measurement for:
• Voltage/Current RMS, updated at 1 cycle with IEC 61557-12 Class 0.1 accuracy
• Frequency, 1mHz accuracy, 40 to 70 Hz
• Voltage/Current harmonics magnitude and angle, up to 127th
• Voltage/Current unbalance
• Flicker
Power quality reporting and analysis
Power quality event detection for:
• Voltage dip/swell/interruption based on 1 cycle RMS
• Current dip/swell based on 1 cycle RMS
• Transient overvoltage based on 32 ksps
Power quality event triggering email notification, or DO/RO Up to 65,535 power quality event logs in circular buffer
Waveform Capture
• Triggered by power quality or manually
• User configurable sample rate up to 512 sample/cycle
• User configurable duration (pre-trigger + post-trigger) from two cycles to two seconds at 512 sample/cycle
• COMTRADE format, download from webpage/SFTP, or post via HTTP(s), FTP, SFTP
Fast Log Capture
• Triggered by power quality or manually
• Capture with 1 cycle RMS
• User configurable duration, same as Waveform Capture
• Fast log report, download from webpage/SFTP, or post via HTTP(s), FTP, SFTP
Reporting
• EN50160 compliance report
• IEEE 519 compliance report
• ITIC (CBEMA) Curve
• SEMI-F47 Curve
Advanced power and energy metering
IEC 62053-22 Class 0.1S active energy measurements
IEC 62053-24 Class 0.5S reactive energy measurements
Import/export/net/total and Four-Quadrant energy measurements
Time of Use (TOU) support:
• Up to eight tariff rates
• Flexible calendar and billing date configuration
• Record current and up to twelve historic billing periods
Communication protocols
• Modbus-RTU via RS485
• Dual ethernet
• WiFi
• Modbus-TCP/IP
• HTTPs Webserver
• HTTP/HTTPs Post
• BACnet-IP
• FTP Post
• SMTP
• SNMP
• SNTP
• DNP3 over IP
• IEC 61850
• PMU
Applications
• Power quality
• Data centers
• Industrial automation
• Manufacturing facilities
• Transportation
• Utilities
• Healthcare
• Telecommunications
• University laboratories